Fix non-coplanar FILLET lines in AutoCAD LT

Two lines can look perfectly flat from above and still sit at different heights. In this example, our cyan line is at Z=0 and both ends of the yellow line are at Z=12. We'll find the mismatch, move the yellow line down and join the corner.

Cyan and yellow lines joined into a sharp corner after matching their Z elevation
Both lines at Z=0, joined with a zero-radius FILLET.

Your turn

Download the practice files

DWG 2018

Tested in AutoCAD LT 2027 for Windows

Download practice ZIP

Watch the demonstration

Watch on YouTube. The video loads when you press play.

Reproduce the problem

Open Practice-before.dwg from the download. Our sample contains two LINE objects. From Top view they look like an ordinary corner that hasn't quite met.

Run FILLET, choose Radius and enter 0. Pick the two lines. AutoCAD reports that the lines are non-coplanar.

  1. FILLET
  2. R
  3. 0
  4. Select the cyan line, then the yellow line
Two separated lines that appear flat in Top view before fixing the elevation
Before: a Top view can hide the difference in height.

Find the line at the wrong height

Press Escape to finish the command. Select only the yellow line and press Ctrl+1 to open Properties. Under Geometry, look at Start Z and End Z: both read 12 in our practice file. The cyan line's endpoints are at 0.

That matching Start Z and End Z matters: the yellow line is flat, but on a different plane. This CHANGE method is for that constant-elevation case when the line should lie at Z=0.

  1. Select the yellow LINE
  2. Ctrl+1 → Geometry
  3. Start Z = 12; End Z = 12

Move the yellow line to Z=0

Run CHANGE. Select the yellow line, press Enter, then choose Properties and Elevation. Enter 0 and press Enter to finish. Here, Properties is an option inside CHANGE; it isn't the separate Ctrl+1 palette.

Select the line again and check Properties. Start Z and End Z should now both be 0. If the two endpoint values differ, this particular constant-elevation fix is not the demonstrated case.

  1. CHANGE
  2. Select yellow line → Enter
  3. P → Enter
  4. E → Enter
  5. 0 → Enter
  6. Enter to finish CHANGE

Retry FILLET and check the result

Run FILLET again, set Radius to 0 and select the two lines near the corner. This time they extend to meet. In our sample the corner is at 100,0,0.

Compare your result with Practice-after.dwg. The useful habit is simple: when a flat-looking corner won't join, check both endpoint Z values before redrawing it.

  1. FILLET → R → 0
  2. Select both lines near the corner
  3. Check: the corner closes at Z=0